Please use this identifier to cite or link to this item: https://repositori.uma.ac.id/handle/123456789/10698
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorIrwan-
dc.contributor.advisorNurma, Nurmaidah-
dc.contributor.authorNasution, Yunita Ariani-
dc.date.accessioned2019-08-20T01:32:44Z-
dc.date.available2019-08-20T01:32:44Z-
dc.date.issued2019-
dc.identifier.urihttps://repositori.uma.ac.id/handle/123456789/10698-
dc.descriptionBeton bertulang sebagai elemen balok harus diberi penulangan yang berupa penulangan lentur dan penulangan geser. Penulangan geser digunakan untuk menahan pembebanan geser yang terjadi pada balok dan mempunyai konsep perhitungan bahwa bagian tulangan sengkang yang berfungsi menahan beban geser adalah bagian pada arah vertikal, sedangkan pada arah horisontal tidak diperhitungkan menahan beban gaya yang terjadi pada balok. Penelitian ini dilakukan untuk mengkaji tentang kekuatan sengkang “U” dan membandingkan dengan kekuatan sengkang konvensional yang telah lazim digunakan. Penelitian ini bertujuan mengetahui beban geser maksimal, kuat geser maksimal, dan besar perbedaannya antara sengkang konvensional dan sengkang “U” pada balok beton bertulang sederhana. Lokasi penelitian adalah di Laboratorium Beton di Prodi Teknik Sipil Universitas Sumatera Utara. Total sampel benda uji yang dibuat sejumlah 4 buah, tiap variasi dibuat 2 sampel. Variasi yang digunakan spasi sengkang 45 mm, ukuran balok lebar 15 cm dan tinggi 15 cm, dengan bentang balok 50 cm. Berdasarkan hasil analisis diketahui bahwa pada beban geser maksimal sebesar 62,6 kN dan kuat geser maksimal sebesar 17,46 kN untuk sengkang konvensional, beban geser maksimal sebesar 56,75 kN dan kuat geser maksimal sebesar 14,53 kN untuk sengkang “U” dan selisih kekuatan geser antara kedua jenis sengkang tersebut sebesar 16,78% dan terjadi pada beban geser sebesar 9,34 %. Dalam penggunaannya, pada sengkang “U” dapat meminimalisir nilai ekonomis, namun tidak terlampau jauh dibanding dengan sengkang konvensional dan selisih kuat geser yang terjadi juga sedikit lebih besar.en_US
dc.description.abstractReinforced concrete as a beam element must be given reinforcement in the form of bending reinforcement and shear reinforcement. Shear reinforcement is used to resist the sliding load that occurs on the beam and has a calculation concept that the shear reinforcement part that serves to hold the shear load is the part in the vertical direction, whereas in the horizontal direction it is not calculated to hold the force load on the beam. This research was conducted to examine the strength of shear reinforcement "U" and compare it with the conventional shear reinforcement strength that is commonly used. This study aims to determine the maximum shear load, maximum shear strength, and the magnitude of the difference between conventional shear reinforcement and "U" shear reinforcement on simple reinforced concrete beams. The research location is at the Concrete Laboratory at the Civil Engineering Study Program, University of North Sumatra. The total sample size of the test specimens was 4, each sample made 2 samples. Variations used is 45 mm sliding spaces, the beam size is 15 cm wide and 15 cm high, with a beam span of 50 cm. Based on the results of the analysis it is known that the maximum load of 62,6 kN and maximum shear strength of 17,46 kN for conventional shear reinforcement, the maximum load of 56,75 kN and maximum shear strength of 14,53 kN for shear reinforcement "U" and the difference in shear strength between the two types of shear reinforcement is 16,78% and happen in load strength is 9,34%. In its use, the "U" shear reinforcement can minimize economic value, but not too far compared to conventional shear reinforcement and the shear strength difference that occurs is also slightly larger.en_US
dc.language.isoiden_US
dc.publisherUniversitas Medan Areaen_US
dc.relation.ispartofseriesNPM;158110102-
dc.subjectkuat geseren_US
dc.subjectsengkang uen_US
dc.subjectsengkang konvensionalen_US
dc.subjectbalok beton bertulangen_US
dc.subjectshear strenghten_US
dc.subjectconventional shearen_US
dc.titlePerbandingan Kuat Geser antara Sengkang Konvensional dan Sengkang "U" pada Balok Beton Bertulangen_US
dc.typeSkripsi Sarjanaen_US
Appears in Collections:SP - Civil Engineering

Files in This Item:
File Description SizeFormat 
158110102 - Yunita Ariani Nasution - Fulltext.pdfFulltext3.46 MBAdobe PDFView/Open