Please use this identifier to cite or link to this item:
https://repositori.uma.ac.id/handle/123456789/11165
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.advisor | Amirsyam | - |
dc.contributor.advisor | Ibrahim, Husin | - |
dc.contributor.author | Panggabean, Daniel | - |
dc.date.accessioned | 2019-11-26T02:18:26Z | - |
dc.date.available | 2019-11-26T02:18:26Z | - |
dc.date.issued | 2019-10 | - |
dc.identifier.uri | https://repositori.uma.ac.id/handle/123456789/11165 | - |
dc.description | Air dipenampungan kamar mandi dapat dimanfaatkan untuk menyejukan ruangan, dengan cara udara yang dilalui pipa Aluminium direndam ke dalam bak air tersebut. Melalui sistim yang telah dirancang sehingga diperoleh laju pendinginan ruangan menggunakan enam sirip Aluminium adalah 31,5254 W. Dari hasil perhitungan laju pendinginan diperoleh bahwa, jika menggunakan empat sirip Aluminium laju pendinginan ruangan model lebih kecil (21,9931 W) begitu juga jika memakai dua sirip Aluminium(4,876 W). Daya yang dibutuhkan 25,9061 Watt selama 5 menit(300 detik) dan komsumsi energi rata-rata yang dibutuhkan selama pengoperasian sistem berlangsung 139893 Joule. Daya yang dibutuhkan 25,9061 Watt selama 5 menit(300 detik) dan komsumsi energi rata-rata yang dibutuhkan selama pengoperasian sistem berlangsung 139893 Joule. | en_US |
dc.description.abstract | Water in the bathroom reservoirs can be utilized to cool the room, through the air pass the Aluminium pipe which is soaked into the water of the tub. Through the designed system, it was obtained the temperature cooling rate using the six fins of Aluminium as much as 31.5254 W. Then, based on the calculation of the temperature cooling rate, it was obtained that in using four fins of Aluminium, the model temperature cooling rate was lower (21.9931 W), as well as using two fins of Aluminium (4.876 W). To sum up, the power needed was 25.9061 Watt for 5 minutes (300 seconds) and the average energy consumptions needed during the operating system was 139893 Joule. | en_US |
dc.language.iso | id | en_US |
dc.publisher | Universitas Medan Area | en_US |
dc.relation.ispartofseries | NPM;148130025 | - |
dc.subject | air temperature | en_US |
dc.subject | aluminium pipe | en_US |
dc.subject | cooling fins | en_US |
dc.subject | suhu udara | en_US |
dc.subject | pipa aluminium | en_US |
dc.subject | sirip pendingin | en_US |
dc.title | Analisis Pengaruh Luas Sirip Alat Penukar Kalor Terhadap Pengkondisian Suhu Ruangan dengan Memanfaatkan Penampung Air Skala Model | en_US |
dc.type | Thesis | en_US |
Appears in Collections: | SP - Mechanical Engineering |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
148130025 - Daniel Panggabean - Fulltext.pdf | fulltext | 4.49 MB | Adobe PDF | View/Open |
148130025 - Daniel Panggabean - Chapter IV.pdf Restricted Access | chapter IV | 1.27 MB | Adobe PDF | View/Open Request a copy |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.