Please use this identifier to cite or link to this item: https://repositori.uma.ac.id/handle/123456789/17055
Title: Analisis Pengaruh Komposit Laminat Hibrid Jute E Glass pada Kekauatan Tekan Beton dengan Metode Anova
Other Titles: Analysis of the Effect of Jute E Glass Hybrid Laminated Composite on the Compressive Strength of Concrete with the Anova Method
Authors: Setiawan, Agus
metadata.dc.contributor.advisor: Siahaan, M Yusuf R
Zulfikar
Keywords: e glass;epoksi;jute;kuat tekan;material komposit;anova;epoxy;compressive strenght;material composite
Issue Date: 29-Mar-2022
Publisher: Universitas Medan Area
Series/Report no.: NPM;168130007
Abstract: Tujuan penelitian ini ialah analisis pengaruh kekuatan tekan mateial komposit laminate hibrid jute e-glass epoksi sebagai penguat struktur beton, mendapatkan variabel yang mempengaruhi kekuatan tekan matetial tersebut. Metode penelitian yang dipergunakan dalam penelitian ini ialah metode Analysis of Variance (Anova). Hasil penelitian ini ialah diperoleh kekuatan tekan maksimum rata-rata pada selubung hibrid KLJG variasi JGJ, yaitu 31,13 MPa atau mengalami peningkatan kekuatan tekan rata-rata hingga 100 % tehadap spesimen tanpa selubung. Hasil analisis terhadap fungsi kerapatan variasi terhadap seluruh data uji menunjukkan bahwa data-data hasil eksperimental tersebut adalah terdistribusi secara normal pada interval populasi memenuhi. Berdasarkan hasil analisis Anova memperlihatkan bahwa nilai F0 hasil eksperimental adalah 0,998 atau jauh lebih kecil jika dibanding dengan nilai F-Distribusi dengan toleransi a = 5 %, DoF treatment = 2, dan DoF error = 6, yaitu 5,14. Dengan demikian, pemberian selubung hibrid KLJG pada spesimen beton silinder terbukti secara signifikan mempengaruhi peningkatan kekuatannya. The purpose of the study is a analysis of the effect power of the material composite of the laminate hybrid jute e-glass epoxy as a concrete structure generator, to get variables affecting the properties of the material pressure. The research method employed in this study is the method analysis of variance (ANOVA). The result of this research is that the average maximum compressive strength of the KLJG hybrid sheath JGJ variation is 31.13 MPa or an increase in the average compressive strength of up to 100% against specimens without sheathing. The results of the analysis of the variation density function on all test data indicate that the experimental data are normally distributed at population intervals that meet P. Based on the results of Anova analysis, it shows that the F0 value of the experimental results is 0.998 or much smaller than the F-Distribution value with tolerance = 5%, DoF treatment = 2, and DoF error = 6, which is 5.14. Thus, the application of KLJG hybrid sheath on cylindrical concrete specimens was proven to significantly affect the increase in strength.
Description: 44 Halaman
URI: https://repositori.uma.ac.id/handle/123456789/17055
Appears in Collections:SP - Mechanical Engineering

Files in This Item:
File Description SizeFormat 
168130007 - Agus Setiawan - Fulltext.pdfCover, Abstract, Chapter I, II, III, V, BIbliography659.85 kBAdobe PDFView/Open
168130007 - Agus Setiawan - Chapter IV.pdf
  Restricted Access
Chapter IV281.58 kBAdobe PDFView/Open Request a copy


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.