Title: Analisis Kekuatan Pondasi Tiang Pancang Pada Proyek Pembangunan Jembatan Jalan Bebas Hambatan Medan-Kualanamu-Tebing Tinggi
Other Titles: Strength Analysis Pile Foundation in Freeway Bridge Construction Project Medan-Kualanamu-High Cliff Barriers
Authors: Askthreed
metadata.dc.contributor.advisor: Hermawan
Hutahuruk, Denny Meisandy
Keywords: Daya Dukung Pondasi Tiang Pancang;Meyerhoff;Converse-Labarre;Pile Foundation Bearing Capacity;Meyerhoff;Converse-Labarre
Issue Date: Jul-2022
Publisher: Universitas Medan Area
Series/Report no.: NPM;198110141
Abstract: Struktur penting pada suatu pembangunan jembatan salah satunya adalah pondasi. Banyak hal yang perlu dipertimbangkan pada saat akan membangun pondasi, mulai dari pemilihan jenis pondasi sampai pada perhitungan beban pondasi tersebut. Maksud dari skripsi ini adalah menganalisa kekuatan pondasi tiang pancang pada proyek pembangunan jembatan jalan jalan bebas hambatan Medan-KualanamuTebing Tinggi. Perhitungan kekuatan pondasi tiang pancang dilakukan dengan menghitung besar daya dukung tiang tunggal dan daya dukung tiang kelompok pada satu abutmen. Daya dukung pondasi tiang pancang dihitung berdasarkan data hasil uji penyelidikan tanah yaitu sondir, Standart Penetration Test (SPT) dan Pile Driving Analyzer (PDA) dengan menggunakan metode Meyerhoff. Berdasarkan hasil perhitungan tiang tunggal, daya dukung kelompok tiang dapat dihitung dengan menggunakan metode Converse-Labarre . Dimensi tiang pancang yang digunakan berbentuk lingkaran dengan diameter 60cm dan panjang tiang 22m. Dari perhitungan yang telah dilakukan dengan metode Meyerhoff, berdasarkan data sondir diperoleh nilai daya dukung tiang tunggal sebesar 200,45 ton. Berdasarkan data Standart Penetration Test (SPT) diperoleh nilai daya dukung tiang tunggal sebesar 260,10 ton. Sedangkan hasil daya dukung yang diperoleh dari data PDA test adalah 299,99 ton. One of the important structures in a bridge construction is the foundation. Many things need to be considered when building a foundation, from choosing the type of foundation to calculating the foundation load. The purpose of this thesis is to analyze the strength of the pile foundation in the construction project of the MedanKualanamu-Tebing Tinggi highway bridge. Calculation of the strength of the pile foundation is carried out by calculating the carrying capacity of single piles and the carrying capacity of group piles in one abutment. The bearing capacity of the pile foundation is calculated based on the data from the soil investigation test results, namely sondir, Standard Penetration Test (SPT) and Pile Driving Analyzer (PDA) using the Meyerhoff method. Based on the calculation of single piles, the bearing capacity of pile groups can be calculated using the Converse-Labarre method. The dimensions of the piles used are circular with a diameter of 60cm and a length of 22m. From the calculations that have been carried out using the Meyerhoff method, based on sondir data, the carrying capacity of a single pile is 200.45 tons. Based on the Standard Penetration Test (SPT) data, the single pile carrying capacity is 260.10 tons. While the results of the carrying capacity obtained from the PDA test data is 299.99 tons.
Description: 80 Halaman
URI: https://repositori.uma.ac.id/handle/123456789/17959
Appears in Collections:SP - Civil Engineering

Files in This Item:
File Description SizeFormat 
198110141 - Askthreed - Fulltext.pdfCover, Abstract, Chapter I,II,III,V Bibliography4.9 MBAdobe PDFView/Open
198110141 - Askthreed - Chapter IV.pdf
  Restricted Access
Chapter IV1.94 MBAdobe PDFView/Open Request a copy


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.