Please use this identifier to cite or link to this item:
https://repositori.uma.ac.id/handle/123456789/21001
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.advisor | - | - |
dc.contributor.author | Simangunsong, Bangun | - |
dc.date.accessioned | 2023-09-06T04:31:21Z | - |
dc.date.available | 2023-09-06T04:31:21Z | - |
dc.date.issued | 2006 | - |
dc.identifier.uri | https://repositori.uma.ac.id/handle/123456789/21001 | - |
dc.description | 56 Halaman | en_US |
dc.description.abstract | Pernitungan sistim pembumian gardu induk pada tugas akhir /skripsi ini adalah menggunakan sistim grid atau sistim kisi-kisi. Pembumian gardu induk ini adalah dilakukan wituk memperoleh harga tahanan pembumian yang sekecil mwigkin agar dapat mengamankan peralatan maupwi manusia yang berada didalam ataupwi diluar gardu induk. Dari basil pengukuran dilapangan diperoleh harga tahanan jenis rata-rata tanah (p) adalah sebesar 25,936 Ohm-meter. Sementara dari basil perhitungan diperoleh besar tegangan mesh lebih kecil dari tegangan sentuh yang diijinkan dan besar tegangan langkah sebenarnya lebih kecil dari tegangan langkah yang diijinkan serta harga tegangan sentuh dan tegangan langkah tersebut masih berada dibawah standart yang diijinkan. Ini menwijukkan bahwa pemilihan jarak kisikisi dan panjang konduktor keseluruhan sudah memenuhi persyaratan dalftm merencanakan suatu sistim gardu induk. Besamya harga tahanan pembumian (Ro) yang diperoleh dari ha.>il pengukuran adalah 0,136 Ohm. Dari basil tersebut dapat disimpulkan bahwa sistim pembumian gardu induk Sei Rotan masih berada dalam batas toleransi keamanan baik wituk mengamankan peralatan maupun manusia yang berada di dalam maupwi di luar gardu induk tersebut karena tahanan pembumian (Ro) yang dihasilkan masih berada dalam batas yang diijinkan oleh pihak PLN yaitu dibawah 5 Ohm. Counting grid transmission system in this thesis is by using b1fid system or bar system. This grid transmission is used to ged the smallest grid resistance. In order to save tools and human inside or out side of grid transmission. The resulf of measuring in field is gotten grid resistance from the average kind of soil is 25,936 ohm meter. White the resulf of counting is gotten mesh mesh voltage less then steps voltage that pennitted and contact voltage and step voltage are less than standard that permitted. This shows that chosing grid distance all length of conductor are fulfilled reguirements in planning a grid transmission system. Grid r~sistance that is gotten from measurement is 0,136 ohm. From this resulf, if can be concluded that grid transmission system Sei Rotan is save for tools and human inside or outside of grid transmission because grid resistance that made is limited by PLN that is 5 ohm. | en_US |
dc.language.iso | id | en_US |
dc.publisher | Universitas Medan Area | en_US |
dc.relation.ispartofseries | NPM;008120057 | - |
dc.subject | evaluasi pentanahan | en_US |
dc.subject | gardu induk | en_US |
dc.subject | grounding evaluation | en_US |
dc.subject | substation | en_US |
dc.title | Studi Evaluasi Pentanahan pada Gardu Induk di Sei Rotan | en_US |
dc.title.alternative | Grounding Evaluation Study at Substations in Sei Rattan | en_US |
dc.type | Skripsi Sarjana | en_US |
Appears in Collections: | SP - Electrical Engineering |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
008120057 - Bangun Simangunsong - Fulltext.pdf | Cover, Abstract, Chapter I, II, III, V, Bibliography | 3.28 MB | Adobe PDF | View/Open |
008120057 - Bangun Simangunsong - Chapter IV.pdf Restricted Access | Chapter IV | 410.74 kB | Adobe PDF | View/Open Request a copy |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.