Please use this identifier to cite or link to this item: https://repositori.uma.ac.id/handle/123456789/21077
Title: Sistem Proteksi Penyulang Tegangan Menengah Di PT PLN Gardu Induk Paya Pasir Medan
Other Titles: Medium Voltage Feeder Protection System at PT PLN Paya Pasir Medan Main Substation
Authors: Sembiring, Bahtra
Keywords: sistem proteksi;penyulang tegangan;voltage feeder;protection system
Issue Date: 2006
Publisher: Universitas Medan Area
Series/Report no.: NPM;008120052
Abstract: Peningkatan proteksi (perlindungan) dari suatu gardu distribusi adalah salah satu cara menunjang aktifitas, efisiensi dan keandalan dalam mencapai suatu tujuan. · Peningkatan mutu produksi dalam hal ini adalah tenaga listrik yang sangat penting dan harus, karena tenaga listrik ini dipergunakan oleh orang banyak. Penyulang tegangan menengah merupakan penyulang tenaga 1istrik yang berfungsi untuk mendistribusikan tenaga tegangan menengah. Pada Penyulang tegangan menengah sering terjadi gangguan, untuk itu diperlukan adanya sistem proteksi yang handal untuk mengatasi gangguan- gangguan yang terjadi pada penyulang tegangan menengah, seperti untuk mencegah atau membatasi daerah - daerah kerusakan SUTM, SKTM beserta peralatannya terhadap gangguan hubung singkat, membatasi daerah yang terganggu sekecil mungkin sehingga pelayanan pada konsumen penyulang lainnya ,masih dapat berlangsung. Selain pada penyulang tegangan menengah proteksi juga dipasang pada peralatan - peralatan dan fasilitas yang ada ada gardu distribusi seperti Relai Arus Lebih ( Over Current relay ) ) ialah suatu relay yang bekerja berdasarkan adanya kenaikan arus yang melebihi suatu nilai pengaman tertentu didalam jangka waktu tertentu, Relai beban Lebih ( Over Load relay ) yang diatur bekerja untuk kelebihan arus yang tak begitu besar, Relai gangguan Tanah ( ground fauld relay )yang berfungsi untuk mendeteksi arus gangguan tanah (Io ), Relay Tegangan lebih ( Over Voltage relay )yang berfungsi untuk mendeteksi naiknya tegangan sampai melewati batas harga tertentu yang dapat merusak isolasi generator, merusak alat-alat pemakai dan sebagainya dan alat - alat proteksi lainnya yang berfungsi mengamankan hila adanya gangguan yang terjadi. Increasing the protection (protection) of a distribution substation is one way supports activities, efficiency and reliability in achieving a goal. · Increasing the quality of production in this case is electricity which is very important and it must be, because this electric power is used by many people. Feeder Medium voltage is an electric power feeder that functions for distribute medium voltage power. On medium voltage feeders Interference often occurs, for this reason a reliable protection system is needed to overcome disturbances that occur in the voltage feeder medium, such as to prevent or limit areas of damage SUTM, SKTM and their equipment against short circuit disturbances, limits The disturbed area is as small as possible so that service to consumers Other feeders can still take place. Apart from the voltage feeder Medium protection is also installed on existing equipment and facilities there are distribution substations such as the Over Current Relay, which is a relay which works based on an increase in current that exceeds a safety value within a certain period of time, the Over Load relay is set to work for a not so large excess current, Ground fault relay (ground fault relay) which functions to detect ground fault current (Io), Over Voltage Relay (Over Voltage relay) which functions to detect increasing the voltage until it exceeds a certain value limit which can damage the insulation generator, damaging user equipment and so on and other protective equipment which functions to protect against disturbances that occur.
Description: 50 Halaman
URI: https://repositori.uma.ac.id/handle/123456789/21077
Appears in Collections:SP - Electrical Engineering

Files in This Item:
File Description SizeFormat 
008120052 - Bahtra Sembiring - Fulltext.pdfCover, Abstract, Chapter I, II, III, V, Bibliography2.69 MBAdobe PDFView/Open
008120052 - Bahtra Sembiring - Chapter IV.pdf
  Restricted Access
Chapter IV908.19 kBAdobe PDFView/Open Request a copy


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.