Please use this identifier to cite or link to this item:
https://repositori.uma.ac.id/handle/123456789/21123
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.advisor | - | - |
dc.contributor.author | Wahid, Muhammad Fazhar | - |
dc.date.accessioned | 2023-09-14T02:47:10Z | - |
dc.date.available | 2023-09-14T02:47:10Z | - |
dc.date.issued | 2010 | - |
dc.identifier.uri | https://repositori.uma.ac.id/handle/123456789/21123 | - |
dc.description | 37 Halaman | en_US |
dc.description.abstract | Salah satu problem yang timbul dalam pengoperasian transformator arus pada sebuah gardu induk adalah terjadinya gangguan atau kesalahan pada sistem tenaga listrik. Gangguan ini dapat menyebabkan kerugian bukan hanya pada peralatan transformator, tetapi juga kerugian yang besar bagi para pemakai jasa tenaga listrik. Pada tugas akhir ini, penulis mencoba mengangkat fenomena kejenuhan pada transformator arus yang notabene berpengaruh pada efisiensi kinerja sistem tenaga listrik pada Gardu Induk PL TG Glugur Medan. Pembahasan dikemukakan terbatas pada hasil pengujian lengkung kemagnetan dan pengujian injeksi primer dan sekunder. One of the problems that arises in the operation of a current transformer in a substation is the occurrence of disturbances or errors in the system electric power. This disruption can cause losses not only to transformer equipment, but also large losses for service users electric power. In this final assignment, the author tries to address the phenomenon of boredom in current transformers which in fact have an effect on the efficiency of system performance electric power at the PL TG Glugur Medan Substation. Discussion is presented limited to the results of magnetic arc testing and primary injection testing and secondary. | en_US |
dc.language.iso | id | en_US |
dc.publisher | UNIVERSITAS MEDAN AREA | en_US |
dc.relation.ispartofseries | NPM;058120019 | - |
dc.subject | transformator arus | en_US |
dc.subject | current transformer | en_US |
dc.title | Kejenuhan Transformator Arus | en_US |
dc.title.alternative | Current Transformer Saturation | en_US |
dc.type | Skripsi Sarjana | en_US |
Appears in Collections: | SP - Electrical Engineering |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
058120019 - Muhammad Fazhar Wahid - Fulltext.pdf | Cover, Abstract, Chapter I, II, III, V, Bibliography | 2.14 MB | Adobe PDF | View/Open |
058120019 - Muhammad Fazhar Wahid - Chapter IV.pdf Restricted Access | Chapter IV | 605.87 kB | Adobe PDF | View/Open Request a copy |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.