Please use this identifier to cite or link to this item: https://repositori.uma.ac.id/handle/123456789/21281
Title: Analisa Sistem Teknologi Pembersih Asap Rokok pada Ruang Keluarga
Other Titles: Analysis of Cigarette Smoke Cleaning Technology Systems in Family Rooms
Authors: Sembiring, Agung Revival
metadata.dc.contributor.advisor: Syah, Rahmat
Keywords: arduino uno;buzzer;adaptor;panel display;exhaust fan AC
Issue Date: Aug-2023
Publisher: Universitas Medan Area
Series/Report no.: NPM;188120063
Abstract: Merokok merupakan bentuk dari sesuatu kegiatan yang sering ditemui di beberapa tempat umum. Melihat dari banyaknya penyakit yang ditimbulkan dari akibat asap rokok, maka pemerintah secara intensif melakukan pencegahan berupa upaya larangan merokok di tempat umum. Kawasan bebas asap rokok sebaiknya diterapkan di rumah, gedung perkantoran, pendidikan, rumah sakit, dan tempat umum lainnya. Selain merugikan kesehatan perokok aktif, asap rokok juga merugikan perokok pasif, saat terpapar asap rokok orang yang tidak merokok (perokok pasif) akan menghirup dua kali lipat racun yang terkandung dalam asap rokok. Untuk itu diperlukan alat yang dapat menyaring asap rokok tersebut. Skripsi ini memiliki tujuan untuk merancang dan menganalisa sebuah teknologi pembersih asap rokok yang akan digunakan pada ruang keluarga (Rumah) berbasis arduino yang berguna untuk membantu masyarakat dalam mengintensifkan kawasan bebas asap rokok. Penelitian ini menggunakan MQ - 7 menggunakan sensor untuk mendeteksi asap, Arduino uno R3 sebagai mikrokontroler, Buzzer sebagai alarm, Adaptor sebagai pemberi daya, Panel Display P10 sebagai memberikan infomasi bahwa area tersebut memiliki asap rokok, Exhaust Fan AC sebagai kipas pembersih asap rokok. Yang diterapkan pada ruang dengan ukuran 2 x 4 m dan dengan kondisi ruangan yang tertutup, Dalam penelitian ini dibuat suatu alat yang dapat meminimalisir asap rokok. Di penelitian ini sensor mq – 7 akan bekerja jika kadar sensor mendekati atau melewati >15 PPM, dengan output kipas exhaust fan dan berputar untuk menghisap asap rokok dalam ruangan, sehingga alat ini dapat membantu, tentunya demi kepentingan dan kenyamanan bersama dalam hal membersihkan ruangan tersebut. Sehingga dapat memberikan kesimpulan bahwa jarak dan tingkat banyak asap sangat berpengaruh terhadap hasil pengukuran kadar ppm, Ruang yang kedap dan tingkat kelembapan sangat berpengaruh besar terhadap hasil dari pengukuran kadar ppm, Penempatan sensor mq – 7 yang tepat dan jarak ketinggian dan letak menentukan hasil pengukuran. Dan Memeliki saran bahwa perlunya menempatkan sensor dengan baik agar pendeteksian dapat dilakukan secara maksimal dan dilakukan diruangan tertutup tanpa ada banyaknya ventilasi udara. Smoking is a form of activity that is often encountered in some public places. Seeing from the many diseases caused by cigarette smoke, the government is intensively preventing efforts to ban smoking in public places. Smoke-free areas should be implemented in homes, office buildings, education, hospitals, and other public places. In addition to harming the health of active smokers, cigarette smoke also harms passive smokers, when exposed to cigarette smoke people who do not smoke (passive smokers) will inhale twice as much as the toxins contained in cigarette smoke. For this reason, a device is needed that can filter the cigarette smoke. This thesis aims to design and analyze a cigarette smoke cleaning technology that will be used in an Arduino-based living room (House) that is useful for helping the community in intensifying smoke-free areas. This study used MQ - 7 using sensors to detect smoke, Arduino uno R3 as a microcodealer, Buzzer as an alarm, Adapter as a power giver, P10 Display Panel as providing information that the area has cigarette smoke, AC Exhaust Fan as a cigarette smoke cleaning fan. Which is applied to a room with a size of 2 x 4 m and with closed room conditions, in this study a tool was made that can minimize cigarette smoke. In this study, the mq-7 sensor will work if the sensor level approaches or passes >15 PPM, with the output of the exhaust fan and rotating to smoke indoor cigarette smoke, so this tool can help, of course, for the sake of mutual interest and comfort in terms of cleaning the room. So that it can provide a conclusion that the distance and level of a lot of smoke greatly affect the results of measuring ppm levels, impermeable spaces and humidity levels are very influential on the results of measuring ppm levels, proper placement of mq – 7 sensors and height and location distances determine the measurement results. And Have a suggestion that it is necessary to place the sensors properly so that the detection can be carried out optimally and carried out in a closed room without the presence of many air vents.
Description: 57 Halaman
URI: https://repositori.uma.ac.id/handle/123456789/21281
Appears in Collections:SP - Electrical Engineering

Files in This Item:
File Description SizeFormat 
188120063 - Agung Revival Sembiring Fulltext.pdfCover, Abstract, Chapter I, II, III, V, Bibliography1.69 MBAdobe PDFView/Open
188120063 - Agung Revival Sembiring Chapter IV.pdf
  Restricted Access
Chapter IV775.74 kBAdobe PDFView/Open Request a copy


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.