Please use this identifier to cite or link to this item: https://repositori.uma.ac.id/handle/123456789/22535
Title: Analisa Sambungan Portal Baja antara Balok dan Kolom dengan Menggunakan Sambungan Las dan Baut
Other Titles: Analysis of Steel Portal Joints between Beams and Columns Using Welded Joints and Bolts
Authors: S, Faber Parlindungan
metadata.dc.contributor.advisor: Hermanto, Edy
Panjaitan, Subur
Keywords: sambungan;portal baja;las;baut;connection;steel frame;weld;bolt
Issue Date: Sep-2014
Publisher: Universitas Medan Area
Series/Report no.: NPM;118110058
Abstract: Pada bangunan gedung yang menggunakan struktur bangunan baja, sambungan merupakan hal yang penting diperhatikan. Karena bangunan baja tidak seperti beton yang konstruksinya adalah monolit sehingga pada konstruksi beton perhatian terhadap sambungan tidak begitu besar. Oleh karena itu Pada bangunan baja harus terdapat sambungan yang menyatukan kolom dan balok tersebut menjadi portal. Sambungan tersebut berguna untuk menyalurkan beban yang terdapat pada balok diteruskan pada kolom dan sambungan tersebut ditunjukkan untuk memindahkan semua momen dan memperkecil atau meniadakan rotasi batang pada sambungan (sambungan portal kaku). Pada perhitungan mekanika teknik, metode yang digunakan adalah metode takabeya. Serta sistem pembebanan dilakukan dengan membagi 2 beban tersebut. Dari data pembebanan yang sudah diperoleh maka dilakukan analisa perhitungan dengan memakai peraturan AISC. · Berdasarkan hasil evaluasi ya.rig dilakukan, diperoleh kesimpulan bahwa pemakaian sambungan baik itu kombinasi antara las dan baut, sambungan baut saja maupun sambungan las saja semuanya semuanya aman digunakan karena tegangan yang terjadi pada sambungan lebih kecil dari tegangan ijin. Namun dari ~egi efisiensi pelaksanaan dilapangan pemakaian sambungan baut merupakan sambungan yang paling efisien, karena pengerjaannya lebih praktis/mudah, juga memiliki kekuatan yang cukup tinggi. Begitu juga dengan kekuatan dari sambungan tersebut dipengaruhi oleh, jumlah baut, susunan baut, jarak antar baut, diameter baut, tebal pelat penyambung, besar gaya yang terjadi begitu juga dengan tebal las. In buildings that use steel structures, connections are important things. Because unlike steel building construction is concrete so that the construction of the concrete monolith attention to the connection is not so great. Therefore, there must be the steel building connections that unite the columns and beams into the portal. The connection is useful to distribute the load contained in the transmitted beam and column connection is shown to move all the moments and minimize or eliminate the rotation rod on the connection (connection rigid portal). In mechanics calculation technique, the method used is the method of takabeya. And system loading is done by dividing the load 2. From the data that has been obtained loading analysis is carried out calculations using the AISC rules. Based on the evaluation results, it is concluded that the combined use of both the connection between welding and bolts, connections bolts or welded joints are only safe to use because it all happened on a voltage lower than the voltage connection permit. But in terms of efficiency of use of the ground connection bolt connection is most efficient, because the process is more practical I easy, also has a high enough power. So is the strength of the connection is influenced by the number of bolts, bolt arrangement, the distance between the bolt, bolt diameter, thick plate with linking large force that occurs as well as welding thick.
Description: 97 Halaman
URI: https://repositori.uma.ac.id/handle/123456789/22535
Appears in Collections:SP - Civil Engineering

Files in This Item:
File Description SizeFormat 
118110058 - Faber Parlindungan S - Fulltext.pdfCover, Abstract, Chapter I, II, III, V, Bibliography5.39 MBAdobe PDFView/Open
118110058 - Faber Parlindungan S - Chapter IV.pdf
  Restricted Access
Chapter IV1.76 MBAdobe PDFView/Open Request a copy


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.