Title: Evaluasi Desain Struktur Gedung Kantor Uppd Medan Utara
Other Titles: Evaluation of the Structural Design of the Uppd North Medan Office Building
Authors: Sitinjak, Sally Veronika R.
metadata.dc.contributor.advisor: Hasibuan, Samsul A Rahman Sidik
Keywords: evaluasi struktur;analisis struktur;perbandingan;structural evaluation;structural analysis;comparison
Issue Date: Aug-2024
Publisher: UNIVERSITAS MEDAN AREA
Series/Report no.: NPM;228110042
Abstract: Saat ini Indonesia telah memasuki era pembangunan dimana infrastruktur tersebut semakin lama semakin meningkat dari tahun ke tahun sehingga harus memperhatikan konstruksi pembangunannya. Pada pelaksanaan proses konstruksi bangunan, sering terjadi bahwa desain struktur bangunan tidak mencapai tingkat kualitas yang diharapkan, mengakibatkan potensi risiko keselamatan dan kinerja bangunan yang kurang optimal. Oleh karena itu, penting untuk melakukan evaluasi terhadap desain struktur bangunan untuk mengevaluasi kecukupan, keandalan dan kinerja strukturalnya. Penelitian ini dilakukan pada proyek Pembangunan Gedung Kantor UPPD Medan Utara. Tujuannya adalah untuk mengevaluasi dan membandingkan hasil desain struktur kolom, balok dan pelat lantai dengan perencanaan awal desain struktur kolom, balok dan pelat lantai. Evaluasi desain struktur ini dilaksanakan dengan melakukan perhitungan ulang berdasarkan kriteria SNI 1726:2019 dan SNI 2847:2019 dan pemodelan struktur menggunakan aplikasi program SAP 2000. Penelitian ini terdiri dari lima tahap yaitu pengumpulan data, analisis pembebanan menggunakan SAP 2000, merekap hasil gaya dalam, analisis perhitungan struktur dan membandingan hasil desain dengan perencanaan awal. Hasil penelitian ini menunjukkan adanya perbedaan antara hasil desain dengan perencanaan awal, perbedaan paling signifikan terjadi pada struktur balok yaitu sebesar 33% pada B1 di posisi lapangan. Currently, Indonesia has entered the era of development where the infrastructure is increasing from year to year so that it must pay attention to its construction development. In the implementation of the building construction process, it often happens that the design of building structures does not reach the expected level of quality, resulting in potential safety risks and suboptimal building performance. Therefore, it is important to evaluate the design of the building structure to evaluate its adequacy, reliability and structural performance. This research was conducted on the UPPD North Medan Office Building Construction project. The purpose is to evaluate and compare the results of the design of column, beam and floor plate structures with the initial planning of the design of column, beam and floor slab structures. The evaluation of this structure design was carried out by recalculating based on the criteria of SNI 1726: 2019 and SNI 2847: 2019 and structural modeling using the SAP 2000 program application. This research consists of five stages, namely data collection, loading analysis using SAP 2000, recapping the results of deep forces, analyzing structural calculations and comparing design results with initial planning. The results of this study showed a difference between the design results and the initial planning, the most significant difference occurred in the beam structure, which was 33% at B1 in the field position.
Description: 129 Halaman
URI: https://repositori.uma.ac.id/handle/123456789/26087
Appears in Collections:SP - Civil Engineering

Files in This Item:
File Description SizeFormat 
228110042 - Sally Veronika R. Sitinjak - Fulltext.pdfCover, Abstract, Chapter I, II, III, V, Bibliography2.6 MBAdobe PDFView/Open
228110042 - Sally Veronika R. Sitinjak - Chapter IV.pdf
  Restricted Access
Chapter IV666.62 kBAdobe PDFView/Open Request a copy


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.