Please use this identifier to cite or link to this item:
https://repositori.uma.ac.id/handle/123456789/26469
Title: | Analisis Kinerja pada Ruang Bakar Boiler Pipa Api Skala Model dengan Tekanan Uap 700 kPa dengan Menggunakan Bahan Bakar Cangkang Kemiri |
Other Titles: | Performance Analysis on Model Scale Fire Tube Boiler Combustion Chamber with 700 kPa Steam Pressure Using Candlenut Shell Fuel |
Authors: | Irfan |
metadata.dc.contributor.advisor: | Idris, Muhammad |
Keywords: | Ruang Bakar;Boiler;Cangkang Kemiri;Combustion Room;Pecan Shell |
Issue Date: | Jun-2024 |
Publisher: | Universitas Medan Area |
Series/Report no.: | NPM;178130015 |
Abstract: | Ketel uap (boiler) adalah sebuah alat yang memiliki fungsi untuk menghasilkan uap panas, dimana memiliki dua bagian yang sangat penting yaitu dapur pemanasan yang mana pemanas didapat dari pembakaran bahan bakar di dalam ruang bakar, dan boiler proper yaitu sebuah alat yang mengubah air menjadi uap panas. Limbah cangkang kemiri mempunyai peluang untuk di manfaatkan secara optimal sebagai energi alternatif yang bermanfaat bagi kebutuhan manyarakat dan ramah terhadap lingkungan. Pemanfaatan di lakukan dengan cara mengubah limbah cangkang kemiri menjadi bahan bakar. Dalam penelitian ini di peroleh hasil Energi panas yang diperlukan untuk mengubah air pada ruang bakar boiler pipa api menjadi Uap dengan hasil 2321,5256 W. kerja pompa pada tekanan 300 kPa yaitu 1,07 kW, energi masuk yaitu 16,23 kW, kerja turbin yaitu 5,18 kW, kerja netto 4,12, energi keluar yaitu 17,29 kW, efisiensi thermal 25,37%, kerja pompa pada tekanan 400 kPa yaitu 1,08 kW, energi masuk yaitu 12,37 kW, kerja turbin yaitu 4,45 kW, kerja netto 13,45, energi keluar yaitu 13,45 kW, efisiensi thermal 28,71%, kerja pompa pada tekanan 500 kPa yaitu 0.95 kW, energi masuk yaitu 9,06 kW, kerja turbin yaitu 3,55 kW, kerja netto 2,60, energi keluar yaitu 10,01 kW, efisiensi thermal 28,71%, kerja pompa pada tekanan 600 kPa yaitu 0,88 kW, energi masuk yaitu 7,30 kW, kerja turbin yaitu 3,06 kW, kerja netto 2,19, energi keluar yaitu 8,18 kW, efisiensi thermal 29,93%, kerja pompa pada tekanan 700kPa yaitu 0,92 kW, energi masuk yaitu 6,82 kW, kerja turbin yaitu 3,03 kW, kerja netto 2,11, energi keluar yaitu 7,73 kW, efisiensi thermal 30,99%. A steam boiler is a device that has the function of producing hot steam, which has two very important parts, namely a heating kitchen, where heating is obtained from burning fuel in the combustion chamber, and a boiler proper, namely a device that converts water into steam. hot. Candlenut shell waste has the opportunity to be utilized optimally as an alternative energy that is beneficial to the needs of the community and is environmentally friendly. Utilization is carried out by converting candlenut shell waste into. In this research, the results obtained were the heat energy required to change the water in the fire pipe boiler combustion chamber into steam with a result of 2321,5256 W. pump work at a pressure of 300 kPa is 1.07 kW, incoming energy is 16.23 kW, turbine work is 5.18 kW, net work is 4.12, outgoing energy is 17.29 kW, thermal efficiency is 25.37%, work pump at a pressure of 400 kPa which is 1.08 kW, incoming energy is 12.37 kW, turbine work is 4.45 kW, net work is 13.45, output energy is 13.45 kW, thermal efficiency is 28.71%, pump work at a pressure of 500 kPa, namely 0.95 kW, incoming energy is 9.06 kW, turbine work is 3.55 kW, net work is 2.60, output energy is 10.01 kW, thermal efficiency is 28.71%, pump work at a pressure of 600 kPa is 0.88 kW, incoming energy is 7.30 kW, turbine work is 3.06 kW, net work is 2.19, output energy is 8.18 kW, thermal efficiency is 29.93%, pump work at a pressure of 700kPa is 0.92 kW, incoming energy is 6.82 kW, turbine work is 3.03 kW, net work is 2.11, outgoing energy is 7.73 kW, thermal efficiency is 30.99%. |
Description: | 47 Halaman |
URI: | https://repositori.uma.ac.id/handle/123456789/26469 |
Appears in Collections: | SP - Mechanical Engineering |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
178130015 - Irfan Fulltext.pdf | Cover, Abstract, Chapter I, II, III, V, Bibliography | 2.15 MB | Adobe PDF | View/Open |
178130015 - Irfan Chapter IV.pdf Restricted Access | Chapter IV | 960.85 kB | Adobe PDF | View/Open Request a copy |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.