Please use this identifier to cite or link to this item: https://repositori.uma.ac.id/handle/123456789/26920
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorJufrizal-
dc.contributor.authorPrasetio, Indra-
dc.date.accessioned2025-03-17T03:19:05Z-
dc.date.available2025-03-17T03:19:05Z-
dc.date.issued2025-02-13-
dc.identifier.urihttps://repositori.uma.ac.id/handle/123456789/26920-
dc.description55 Halamanen_US
dc.description.abstractTujuan Penelitian ini untuk mengetahui dan menganalisis kinerja cooling water pada mesin Stirling mCHPSE-012021. Dengan tujuan khusus untuk mengidentifikasi parameter yang mempengaruhi kinerja cooling water serta mengembangkan metode pengujian untuk evaluasi kinerja cooling water dan menyediakan rekomendasi untuk meningkatkan efisiensi cooling water. Metode penelitian ini dilakukan secara eksperimental dengan hasil dari penelitian cooling water ini menunjukkan temperatur air masuk pada suhu 27,6 oC dan temperatur rata-rata air yang keluar mencapai suhu 92,33 oC, dengan pengujian selama 1 jam, dengan pengujian selama 60 menit menunjukkan cooling water dengan suhu masuk 27,6 oC mampu menurunkan temperatur sumber panas rata-rata 484,51 oC menjadi 64,78 oC pada sisi ruang kompresinya, pada 𝑉 ̇ Air 0,006 m3/s terjadi kenaikan nilai efektivitas pendingin dengan rata-rata mencapai 14%, dengan titik tertinggi 19,1% pada menit 55, pada pengujian selama 60 menit The purpose of this study is to determine and analyze the performance of cooling water in the Stirling engine mCHPSE-012021. The specific objectives are to identify the parameters affecting the performance of the cooling water, develop testing methods for evaluating cooling water performance, and provide recommendations to improve cooling water efficiency. This research was conducted experimentally, and the results show that the inlet water temperature was 27.6°C, while the average outlet water temperature reached 92.33°C during a 1-hour test. The testing showed that cooling water with an inlet temperature of 27.6°C could reduce the average heat source temperature from 484.51°C to 64.78°C on the compression chamber side. At an air flow rate 𝑉 ̇ of 0.006 m³/s, there was an increase in cooling effectiveness, with an average of 14%, peaking at 19.1% at the 55 minute, during a 60 minute test.en_US
dc.language.isoiden_US
dc.publisherUNIVERSITAS MEDAN AREAen_US
dc.relation.ispartofseriesNPM;188130009-
dc.subjectuji kinerja cooling wateren_US
dc.subjectmesin stirlingen_US
dc.subjecttemperatur kompresi (tc)en_US
dc.subjectefektivitasen_US
dc.subjectcooling water performance testen_US
dc.subjectstirling engineen_US
dc.subjectcompression temperature (tc)en_US
dc.subjecteffectiveness (e)en_US
dc.titlePengujian Kinerja Cooling Water untuk Mesin Stirling Mchpse-012021en_US
dc.title.alternativeCooling Water Performance Testing for Stirling Engine Mchpse-012021en_US
dc.typeSkripsi Sarjanaen_US
Appears in Collections:SP - Mechanical Engineering

Files in This Item:
File Description SizeFormat 
188130009 - Indra Prasetio - Fulltext.pdfCover, Abstract, Chapter I, II, III, V, Bibliography1.46 MBAdobe PDFView/Open
188130009 - Indra Prasetio - Chapter IV.pdf
  Restricted Access
Chapter IV513.67 kBAdobe PDFView/Open Request a copy


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.