Please use this identifier to cite or link to this item: https://repositori.uma.ac.id/handle/123456789/28106
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorJufrizal-
dc.contributor.authorNababan, Josua Panto-
dc.date.accessioned2025-08-26T01:58:22Z-
dc.date.available2025-08-26T01:58:22Z-
dc.date.issued2025-03-17-
dc.identifier.urihttps://repositori.uma.ac.id/handle/123456789/28106-
dc.description66 Halamanen_US
dc.description.abstractPenelitian ini bertujuan untuk menganalisis konsumsi energi listrik di Gedung Suzuya T.B Simatupang Medan dalam upaya penghematan energi. Rumusan masalah yang dibahas adalah besarnya pemakaian energi listrik di gudang serta kesesuaiannya dengan standar yang telah ditetapkan. Metode yang digunakan adalah observasi langsung terhadap penggunaan energi listrik di gedung tersebut. Hasil penelitian menunjukkan bahwa pencahayaan ruangan bakery seluas 80 m2 dengan 16 titik lampu TL 18 watt belum memenuhi standar SNI yang mempersyaratkan minimal 500 lux untuk area produksi. Selain itu, nilai Intensitas Konsumsi Energi (IKE) sebesar 1.009,2 kWh/m2/tahun di ruangan bakery tersebut juga dianggap tidak memenuhi standar dan perlu dilakukan audit energi lebih lanjut untuk mengidentifikasi peluang penghematan energi. Temuan ini menunjukkan perlunya perbaikan sistem pencahayaan dan upaya penghematan energi di gedung tersebut. Rekomendasi yang diberikan meliputi penambahan jumlah titik lampu atau penggunaan lampu dengan daya yang lebih besar, optimalisasi susunan lampu, serta pemilihan armatur yang lebih efisien. Selain itu, audit energi menyeluruh juga perlu dilakukan untuk mengidentifikasi peluang penghematan lainnya seperti mengganti peralatan boros energi dan memanfaatkan pencahayaan alami. This study aims to analyze electrical energy consumption in the Suzuya T.B Simatupang Building, Medan, in an effort to save energy. The problem formulation discussed is the amount of electrical energy consumption in the warehouse and its compliance with established standards. The method used is direct observation of electrical energy use in the building. The results of the study indicate that the lighting of the 80 m2 bakery room with 16 18-watt TL lamps does not meet the SNI standard which requires a minimum of 500 lux for production areas. In addition, the Energy Consumption Intensity (IKE) value of 1,009.2 kWh/m2/year in the bakery room is also considered not to meet the standard and requires further energy audits to identify energy saving opportunities. These findings indicate the need for improvements to the lighting system and energy saving efforts in the building. Recommendations given include increasing the number of light points or using lamps with higher wattage, optimizing the arrangement of lamps, and selecting more efficient armatures. In addition, a comprehensive energy audit is also needed to identify other saving opportunities such as replacing energy-wasting equipment and utilizing natural lighting.en_US
dc.language.isoiden_US
dc.publisherUniversitas Medan Areaen_US
dc.relation.ispartofseriesNPM;188130101-
dc.subjectpenghematan energyen_US
dc.subjectenergy savingen_US
dc.titleAnalisis Konsumsi Energi Listrik di Gedung Suzuya TB. Simatupang dalam Upaya Penghematan Energien_US
dc.title.alternativeAnalysis of Electrical Energy Consumption in the Suzuya Building, TB. Simatupang, as a Part of Energy Saving Effortsen_US
dc.typeThesisen_US
Appears in Collections:SP - Mechanical Engineering

Files in This Item:
File Description SizeFormat 
188130101 - Josua Panto Nababan - Chapter IV.pdf
  Restricted Access
Chapter IV321.4 kBAdobe PDFView/Open Request a copy
188130101 - Josua Panto Nababan - Fulltext.pdfCover, Abstract, Chapter I, II, III, V, Bibliography1.42 MBAdobe PDFView/Open