Title: Analisis Struktur Gedung Pengadilan Tinggi Tata Usaha Negara Medan terhadap Beban Gempa
Other Titles: Structural Analysis of the Medan High Administrative Court Building Against Earthquake Loads
Authors: Sihotang, Daniel Parulian
metadata.dc.contributor.advisor: Hermansyah
Keywords: Respon Spektrum;Displacement;Story Drift;Base Shear
Issue Date: Sep-2025
Publisher: Universitas Medan Area
Series/Report no.: NPM;218110036
Abstract: Gedung Pengadilan Tinggi Tata Usaha Negara Medan, sebagai salah satu fasilitas hukum yang memiliki peran vital dalam penyelenggaraan keadilan di wilayah Sumatera Utara. Salah satu ancaman terbesar terhadap struktur gedung adalah beban gempa, terutama di daerah zona gempa aktif. Salah satu aspek dalam mendesain gedung bertingkat adalah analisis dinamis, yang melibatkan respons struktur terhadap beban gempa. Metode response spectrum adalah metode analisis struktur bangunan dengan menggunakan spektrum gempa yang digambarkan dalam bentuk kurva hubungan antara periode struktur bangunan dengan nilai percepatan bangunan itu sendiri ketika terkena beban gempa. Nilai displacement terbesar dari arah X sebesar 21,89497mm dan pada arah Y sebesar 17,363304 mm. Berdasarkan analisis Story Drift yang telah dilakukan didapatkan nilai story drift terbesar terdapat pada lantai dak. Pada lantai dak nilai story dirft pada arah X sebesar 60,993 mm dan pada arah Y sebesar 50,002 mm. Berdasarkan analisi ragam respons spectrum pada arah X dan Y menghasilkan nilai Vdinamik ≥ 100% Vstatik yaitu , dengan nilai arah X yaitu Vxdinamik 4642,989 kN dan Vxstatik 4642,913 kN, kemudian arah Y yaitu Vydinamik 4643,013 kN dan Vystatik 4642,913 kN. Nilai pada partisipasi massa ragam terkombinasi arah X dan Arah Y sudah memenuhi dengan hasil yaitu 100% pada mode ke 7. The Medan State Administrative High Court building, a legal facility, plays a vital role in administering justice in North Sumatra. One of the greatest threats to building structures is earthquake loads, especially in active earthquake zones. One aspect of designing multi-story buildings is dynamic analysis, which involves the structure's response to earthquake loads. The response spectrum method is a structural analysis method that uses the earthquake spectrum, which is depicted in the form of a curve representing the relationship between the period of the structure and the acceleration of the building itself when subjected to earthquake loads. The largest displacement value in the X direction was 21.89497 mm and in the Y direction was 17.363304 mm. Based on the story drift analysis, the largest story drift value was found on the floor slab. On the floor slab, the story drift value in the X direction was 60.993 mm and in the Y direction was 50.002 mm. Based on the response spectrum analysis, the X and Y directions yielded Vdynamic values ​​≥ 100% of Vstatic, with Vxdynamic values ​​of 4642.989 kN and Vxstatic values ​​of 4642.913 kN in the X direction, and Vydynamic values ​​of 4643.013 kN and Vystatic values ​​of 4642.913 kN in the Y direction. The combined mass participation values ​​for the X and Y directions met the requirements, achieving 100% in mode 7.
Description: 88 Halaman
URI: https://repositori.uma.ac.id/handle/123456789/28997
Appears in Collections:SP - Civil Engineering

Files in This Item:
File Description SizeFormat 
218110036 - Daniel Parulian Sihotang - Chapter IV.pdf
  Restricted Access
Chapter IV3.4 MBAdobe PDFView/Open Request a copy
218110036 - Daniel Parulian Sihotang - Fulltext.pdfCover, Abstract, Chapter I, II, III, V, Bibliography2.45 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.