Please use this identifier to cite or link to this item:
https://repositori.uma.ac.id/handle/123456789/30109| Title: | Analisa Arus Harmonisa pada Pemasangan PV terhubung Grid PLN Menggunakan Beban Listrik Rumah Tangga |
| Authors: | Solin, Rizky Franto |
| metadata.dc.contributor.advisor: | Satria, Habib |
| Keywords: | Harmonisa;Sistem On Grid;Photovoltaik;Inverter;Harmonics;On-Grid System;Photovoltaics |
| Issue Date: | Sep-2024 |
| Publisher: | Universitas Medan Area |
| Series/Report no.: | NPM;188120056 |
| Abstract: | Harmonisa merupakan pengoperasian listrik dari beban non liner sehingga terbentuklah gelombang frekuensi tinggi yang merupakan kelipatan dari frekwensi dasar 50 Hz atau 60 Hz, sehingga bentuk gelombang arus maupun tegangan yang idealnya adalah sinusoidal murni akan menjadi cacat. Pada sistem potovoltaik on grid pasti memiliki arus harmonisa yang kita tidak ketahui. Jika harmonisa pada sisrtem on grid sangat besar ini mengakibatkan terjadinya panas berlebihan pada perlatan dan menyebabkan terjadinya kebakaran. maka peneliti menganalisa arus harmonisa pada pemasanngan pv terhubung grid pln menggunakan beban listrik rumah tangga. Dan hasil dari menganalisa ini memiliki dua pengujian yang pertama pengukuran dan yang kedua melihat gelombang. Pengukuran yang dilakukan dengan daya tertinggi sekitar 265,9 watt. Setelah pengukuran lalu melihat gelombang pada osiloskop. Hasil yang terlihat pada penggunaan sistem on grid ini bahwasanya ketika tanpa ada nya beban gelombang yang dihasilkan yaitu sinussoidal sementara pemakaian beban pada gelombangnya yaitu tidak sinussoidal berarti memiliki gelombang yang cacat atau gelombang harmonisa. Dampak terjadinya harmonis pada sistem on grid ialah membuat inverter cepat panas. Jika inverter cepat panas ini mengakibatkan kerusakan pada komponen yang ada di inverter. Ketika komponen rusak maka inverter tidak dapat bekerja dan energi dari panel surya tidak dapat disuplay lagi jadi cuman energi pln yang terpakai saja. Harmonics refer to the electrical operation of non-linear loads, resulting in high- frequency waves that are multiples of the fundamental frequency of 50 Hz or 60 Hz. Consequently, the current and voltage waveforms, which ideally should be purely sinusoidal, become distorted. In on-grid photovoltaic systems, harmonic currents are inevitable and often unknown. Excessive harmonics in an on-grid system can lead to overheating of equipment and pose a fire hazard. Therefore, this research analyzed harmonic currents in a PV system connected to the PLN grid using household electrical loads. The analysis involved two tests: measurement and waveform observation. Measurements were conducted with a peak power of approximately 265.9 watts. After measurement, the waveform was observed using an oscilloscope. The results showed that, without a load, the waveform produced was sinusoidal. However, with a load, the waveform was non- sinusoidal, indicating distortion or harmonics. The impact of harmonics in the on- grid system is that the inverter heats up quickly. Excessive heating of the inverter can lead to damage to its components. When the components are damaged, the inverter cannot operate, and energy from the solar panels cannot be supplied, leaving only energy from the PLN grid to be utilized |
| Description: | 33 Halaman |
| URI: | https://repositori.uma.ac.id/handle/123456789/30109 |
| Appears in Collections: | SP - Electrical Engineering |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| 188120056 - Rizky Franto Solin - Fulltext.pdf | Cover, Abstract, Chapter I, II, III, V, Bibliography | 966.91 kB | Adobe PDF | View/Open |
| 188120056 - Rizky Franto Solin - Chapter IV.pdf Restricted Access | Chapter IV | 380.19 kB | Adobe PDF | View/Open Request a copy |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.