Please use this identifier to cite or link to this item: https://repositori.uma.ac.id/handle/123456789/30362
Title: Analisis Daya Dukung Spun Pile Berbasis Data Spt Melalui Pendekatan Analitik dan Pemodelan Software
Other Titles: Analysis of Spun Pile Bearing Capacity Based on SPT Data Using Analytical Approaches and Software Modeling
Authors: Tampubolon, Dicky Hamdani
metadata.dc.contributor.advisor: Wulandari, Tika Ermita
Keywords: Spun Pile;Daya Dukung;SPT;Bearing Capacity
Issue Date: Mar-2026
Publisher: Universitas Medan Area
Series/Report no.: NPM;228110021
Abstract: Pondasi adalah elemen struktural yang krusial karena menopang seluruh beban bangunan. Di lokasi penelitian, kondisi tanah bervariasi dan kompleks, terdiri dari lapisan lempung dan pasir dengan daya dukung yang tidak merata, sehingga evaluasi kapasitas pondasi yang akurat sangat penting. Penelitian ini membandingkan daya dukung spun pile melalui perhitungan Analitik menggunakan metode Luciano Decourt dan Numerik menggunakan Software GEO5 dengan uji lapangan menggunakan PDA Test yang diperoleh dari lokasi penelitian sebagai acuan. Nilai SPT digunakan sebagai input pada kedua metode Analisis, hasil menunjukkan bahwa daya dukung Analitik metode Luciano Decourt sebesar 202,41 Ton, sedangkan pemodelan software GEO5 menghasilkan daya dukung sebesar 361,48 Ton. Berdasarkan hasil analisis, metode Numerik menggunakan software GEO5 menunjukkan nilai daya dukung yang lebih tinggi dibandingkan dengan hasil PDA Test sebesar 296,7 Ton yang dijadikan sebagai data acuan, sehingga metode Numerik memberikan tingkat keamanan yang lebih besar. Oleh karena itu, Metode Numerik menggunakan software GEO5 ini dapat digunakan sebagai referensi dalam perencanaan pondasi tiang pada kondisi tanah dan karakteristik struktur yang serupa. Foundations are crucial structural elements because they support the entire load of a building. At the research site, the soil conditions are varied and complex, consisting of clay and sand layers with uneven bearing capacity; therefore, accurate evaluation of foundation capacity is essential. This study compares the bearing capacity of spun piles using an analytical calculation based on the Luciano Decourt method and a numerical analysis using GEO5 software, with field test results from a PDA Test at the research location used as a reference. SPT values were used as input parameters for both analysis methods. The results show that the analytical method using Luciano Decourt yields a bearing capacity of 202.41 tons, while modeling with GEO5 software produces a bearing capacity of 361.48 tons. Based on the analysis results, the numerical method using GEO5 software indicates a higher bearing capacity value compared to the PDA Test result of 296.7 tons, which serves as the reference data, thus providing a higher level of safety. Therefore, the numerical method using GEO5 software can be used as a reference in the design of pile foundations under similar soil conditions and structural characteristics.
Description: 77 Halaman
URI: https://repositori.uma.ac.id/handle/123456789/30362
Appears in Collections:SP - Civil Engineering

Files in This Item:
File Description SizeFormat 
228110021 - Dicky Hamdani Tampubolon - Fulltext.pdfCover, Abstract, Chapter I, II, III, V, Bibliography1.98 MBAdobe PDFView/Open
228110021 - Dicky Hamdani Tampubolon - Chapter IV.pdf
  Restricted Access
Chapter IV835.13 kBAdobe PDFView/Open Request a copy


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.