Title: Analisis Kekuatan Kolom Gedung The Reiz Condo Medan Pasca Kebakaran
Other Titles: Analysis of the Column Strength of The Reiz Condo Medan Building after the Fire
Authors: Simamora, Odeth Claudia Magdalena
metadata.dc.contributor.advisor: advisor
Keywords: kolom gedung;pasca kebakaran;post fire
Issue Date: 15-Oct-2021
Publisher: Universitas Medan Area
Series/Report no.: NPM;188110143
Abstract: Struktur dapat mengalami kegagalan jika kekuatannya dalam menahan beban tidak lebih besar daripada beban yang dipikulnya, sehingga dilakukan perkuatan dengan menggunakan jacketing baja (steel jacketing). Maka, dilakukan analisis kolom struktur bangunan gedung pasca kebakaran pada kolom 2D’ dan 3D’ untuk menentukan apakah metode steel jacketing dapat digunakan untuk meningkatkan mutu kolom struktur gedung. Berdasarkan data yang didapat dari hasil Ultrasonic Pulse Velocity test, kebakaran yang terjadi pada The Reiz Condo Medan mengakibatkan kolom struktur pada as 3/D’ sebesar 27,52%, as 2/D’ sebesar 37,4% mengalami penurunan mutu yang signifikan. Setelah dilakukan analisis komputasi dengan menggunakan software ETABS, didapatkan nilai kapasitas maksimum adalah dari kombinasi 3, beban aksial pada analisis kolom as 2/D' yaitu 16101,65 N dan 3/D’ yaitu 3069,24 N. Setelah dilakukan analisis komputasi dengan menggunakan software ETABS 9.7.1, didapatkan nilai kapasitas maksimum torsi pada analisis kolom as 2/D' yaitu 1627,310 Nm dan 3/D’ yaitu 1459,331 Nm. Dari perbandingan yang didapat dari hasil analisis kolom, didapatkan bahwa metode perkuatan yang digunakan (steel jacketing) dapat meningkatkan kapasitas maksimum pada kolom yang mengalami penurunan mutu.-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------The structure can fail if its strength to withstand the load is not greater than the load it bears, so that reinforcement is carried out using steel jacketing. Thus, an analysis of the post-fire structure column was carried out in the 2D' and 3D' columns to determine whether the steel jacketing method can be used to improve the quality of the building's structural columns. Based on the data obtained from the results of the Ultrasonic Pulse Velocity test, the fire that occurred at The Reiz Condo Medan resulted in the structural column on the 3/D' axle by 27.52%, 2/D' axle by 37.4% experiencing a significant decrease in quality. After performing computational analysis using ETABS software, the maximum capacity value is obtained from the combination of 3, the axial load on the column axle analysis 2/D' is 16101.65 N and 3/D' is 3069.24 N. After performing computational analysis using software ETABS 9.7.1, the maximum torque capacity value in the analysis of the 2/D' axle column is 1627.310 Nm and 3/D' is 1459.331 Nm. From the comparison obtained from the results of column analysis, it was found that the reinforcement method used (steel jacketing) can increase the maximum capacity o f the column that has decreased quality.
Description: 56 Halaman
URI: https://repositori.uma.ac.id/handle/123456789/17571
Appears in Collections:SP - Civil Engineering

Files in This Item:
File Description SizeFormat 
188110143 - Odeth Claudia Magdalena Simamora - Fulltext.pdfCover, Abstract, Chapter I,II,III,Bibliography4.07 MBAdobe PDFView/Open
188110143 - Odeth Claudia Magdalena Simamora - Chapter IV.pdf
  Restricted Access
Chapter IV734.06 kBAdobe PDFView/Open Request a copy


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.