Title: | Analisis Penutup Balik Otomatis Sebagai Pengaman Gangguan Sistem Distribusi Menggunakan Perangkat Lunak Matlab |
Other Titles: | Analysis of Automatic Back Covers as Protection for Distribution System Disturbances Using Matlab Software |
Authors: | Efendi, Yusuf |
Keywords: | MV Asc;hubungan singkat;matlab;short circuit |
Issue Date: | 2011 |
Publisher: | Universitas Medan Area |
Series/Report no.: | NPM;088120038 |
Abstract: | Gangguan pada sistem tenaga listrik yang bersifat sementara akan mengakibatkan terbukanya Recloser (Pemutus), sehingga penyaluran energi listrik kepada konsumen tertunda untuk waktu yang lama, dan Penutup Balik Otomatis (Recloser) dapat mengatasi hal tersebut. Alat ini dapat secara otomatis bekerja untuk menutup kembali pemutus tenaga dalam waktu yang relatif singkat. Sedangkan gangguan yang bersifat tetap (permanen), Penutup Balik Otomatis akan menutup beberapa kali dan setelah melewati settingnya alat ini akan membuka dan tidak mampu lagi menutup (Lock Out). Kemampuan pemutus menahan arus gangguan sebelum pemutus tersebut mengisolir gangguan dilakukan dengan serangkaian pengujian hubung singkat simetris dan anal isis MV A Short Circuit sehingga dilakukan penelitian tentang Analisis Penutup Balik Otomatis Sebagai Pengaman Gangguan Sistem Distribusi Menggunakan Perangkat Lunak Matlab Dari serangkaian pengujian menggunakan Matlab dan hasil analisis diperoleh besar kapasitas pemutus untuk menanggung arus gangguan tersebut sebelum gangguan di isolir adalah: 519,262260 MV A. Disturbances of the power system will result in a temporary opening of the Recloser (Breaker), so distribution of electrical energy to consumers delayed for a long time, and Auto Flip Cover (Recloser) can overcome this. This tool can automatically work to close the circuit breaker in a relatively short time. While the disorder is fixed (permanent), Auto Flip Cover will close a few times and after going through the settings of these tools will not be able to open and close again (Lock Out). Fault current withstand capability breaker before the circuit breaker to isolate the interference conducted a series of tests and analysis of the symmetrical short circuit MVA Short Circuit to do research on Analysis of Flip Cover For Safety Automatic Distribution System Disorders Using Matlab Software Of a series of tests using Matlab and results obtained by analysis of the breaker capacity to bear the fault current before disruption in isolir are: 519,262,260 MV |
Description: | 43 Halaman |
URI: | https://repositori.uma.ac.id/handle/123456789/21158 |
Appears in Collections: | SP - Electrical Engineering |