Title: | Kontrol Pengkondisian Udara di Gedung Bank Sumut Medan |
Other Titles: | Air Conditioning Control in the North Sumatra Bank Building, Medan |
Authors: | Siregar, Awaluddin M. |
metadata.dc.contributor.advisor: | - |
Keywords: | kontrol pengkondisian udara;air conditioning control |
Issue Date: | 2002 |
Publisher: | Universitas Medan Area |
Series/Report no.: | NPM;978120026 |
Abstract: | KESIMPULAN Dari hasil penulisan dapat ditarik kesimpulan sebagai berikut : 1. Penggunaan sistem pengkondisian udara di Gedung Bank Sumut Medan bertujuan untuk : a. Menjaga temperatur ruangan komputer pada kondisian tetap ( 23 ° C ) b. Menjaga temperatur ruangan pelanggan pada kondisi tetap ( 23 ° C ) 2. a. Terjadi penurunan temperatur pada ruangan , 1 sampai 5 di lantai II karena jumlah kompresor AC 2 buah. b. Terj adi kenaikan temperatur pada ruangan 1 sampai 5 di lantai Ill karena jumlah kompresor AC 1 buah. 3. Pengaturan temperatur kondisi udara didasarkan keinginan pelanggan 4. Peralatan pengkondisian udara yang mempengaruhi stabilitas temperatur adalah: a. Kompresor b. Kondensor c. Evaporator 5. Kompresor akan berhenti bekerja apabila temperatur yang diinginkan telah tercapai. CONCLUSION From the results of this writing, the following conclusions can be drawn: 1. Use of the air conditioning system in the Bank Sumut Medan Building aims to : a. Maintain the temperature of the computer room at a constant condition (23 ° C) b. Maintain the customer's room temperature at a constant condition (23 ° C) 2. a. There was a decrease in temperature in the room, 1 to 5 on the second floor because number of AC compressors 2 pieces. b. There was an increase in temperature in rooms 1 to 5 on the 1st floor because number of AC compressors 1 piece. 3. Air condition temperature settings are based on customer wishes 4. Air conditioning equipment that affects temperature stability is: a. Compressor b. Condenser c. Evaporator 5. The compressor will stop working when the desired temperature is reached achieved. |
Description: | 70 Halaman |
URI: | https://repositori.uma.ac.id/handle/123456789/22400 |
Appears in Collections: | SP - Electrical Engineering |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
978120026 - Awaluddin M.Siregar - Fulltext.pdf | Cover, Abstract, Chapter I, II, III, V, Bibliography | 3.98 MB | Adobe PDF | View/Open |
978120026 - Awaluddin M.Siregar - Chapter IV.pdf Restricted Access | Chapter IV | 700.66 kB | Adobe PDF | View/Open Request a copy |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.