Please use this identifier to cite or link to this item: https://repositori.uma.ac.id/handle/123456789/12730
Title: Analisa Rugi Rugi Daya Pada Penghantar SUTET 275 KV Pangkalan Susu - Binjai
Other Titles: Power Loss Analysis on SUTET Deliverers 275 KV Pangkalan Susu - Binjai
Authors: Manullang, Rihotlian
metadata.dc.contributor.advisor: Bahri, Zulkifli
Putri, Syarifah Muthia
Keywords: transmisi;resistensi;efisiensi;transmission;resistance;efficiency
Issue Date: 2-Oct-2020
Publisher: Universitas Medan Area
Series/Report no.: NPM;168120002
Abstract: Saluran transmisi memiliki peran dalam penyaluran daya dari pembangkit ke beban. Analisa terhadap rugi-rugi daya pada penghantar transmisi dilakukan untuk mengetahui besaran rugi-rugi daya yang terjadi dalam penyaluran daya. Dengan mengetahui besaran rugi-rugi daya, dapat dilakukan tindakan untuk mengurangi daya yang hilang. Penelitian bertujuan untuk mengetahui rugi – rugi daya yang terjadi pada penghantar SUTET Pangkalan Susu – Binjai juga melakukan menghitung regulasi tegangan pada penghantar tersebut. Data untuk penelitian diperoleh dari logsheet harian dan diambil pada pukul 10.00, 19.00 dan 24.00, lalu dilakukan perhitungan rugi – rugi dan regulasi tegangan dengan menggunakan rumus. Hasil yang diperoleh yaitu nilai efisiensi transmisi rata – rata sebesar 99,16% dengan rugi-rugi daya sebesar 0,84% dan regulasi tegangan pada penghantar Pangkalan susu – Binjai rata – rata sebesar 1,93% . Transmission line plays a role in power transferring power station to load. The analysis of power losses transmission line was done for finding out the extent of power losses that were occurred in power transferring. By knowing the extent of power losses, an action could be done for reducing the lost power. This research was done for knowing the power losses that were occurred in EHV Transmission line Pangkalan susu – Binjai and also calculating the voltage regulation on that line. Datas for this research were obtained from daily logsheet. They were taken at 10 am, 7 pm and 12 pm. The calculation of power losses and voltage regulation was done by using the formula. The result shown the average value of transmission efficiency as 99.16% with power losses as 0.84% and average value of voltage regulation as 1.93%
URI: http://repository.uma.ac.id/handle/123456789/12730
Appears in Collections:SP - Psychology

Files in This Item:
File Description SizeFormat 
168120002 - Rihotlian Manullang - Chapter IV.pdf
  Restricted Access
Chapter IV411.81 kBAdobe PDFView/Open Request a copy
168120002 - Rihotlian Manullang - Fulltext.pdfCover, Abstract, Chapter I,II,III,Bibliography2.36 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.