DC Field | Value | Language |
---|---|---|
dc.contributor.advisor | Irwan | - |
dc.contributor.advisor | Lubis, Kamaluddin | - |
dc.contributor.author | Sitompul, Beni Deni | - |
dc.date.accessioned | 2021-12-16T07:54:30Z | - |
dc.date.available | 2021-12-16T07:54:30Z | - |
dc.date.issued | 2021-09-01 | - |
dc.identifier.uri | https://repositori.uma.ac.id/handle/123456789/15639 | - |
dc.description | 106 Halaman | en_US |
dc.description.abstract | tanah untuk mendukung beban konstruksi bagian atas. Kondisi tanah di bawah struktur sangat berkaitan dengan perilaku tanah itu sendiri ketika menerima beban, misalnya kegagalan yang terjadi pada sub-grade pondasi timbunan yakni tanah pondasi terlalu lunak sehingga daya dukung tanah dalam menahan beban timbu-nan kecil, akibatnya settlement yang terjadi terlalu besar. Maka lapisan tanah yang ada di bawah struktur tersebut haruslah kuat, stabil, aman, agar tidak mengalami penurunan, tidak mengalami patah, karena akan sulit untuk memperbaiki suatu sistem pondasi. Tujuan dalam penelitian ini adalah untuk mengetahui pengaruh tanah timbunan pada suatu pondasi telapak dan berapa besar penurunan yang ditimbulkan terhadap pondasi. Metode Plaxis D2 V20 adalah metode elemen hingga yang bertujuan dalam menganalisis dan mendesign bidang geoteknik. Pengambilan sampel tanah dilakukan di RS. Wulan Windi Kota Medan, dengan menggunakan alat manual. Penyelidikan tanah timbunan bertujuan untuk menge-tahui sifat dan karakteristik tanah timbunan yang dilakukan di Laboratorium Teknik Sipil Universita Medan Area dan dilaboratorium Politeknik Negeri Me-dan. Hasil penelitian tanah timbunan diperoleh berat jenis tanah (Gs) = 2,63 gr, Berat volume tanah basah (γb) = 14,8512 kN/m3, Berat volume tanah kering (yd) = 0,3236 kN/m3, Permeabilitas tanah (K)= 12,929 cm/jam, tegangan geser (o) = 23,610 . Kohesi tanah (c) = 0.057 kg/cm2, Modulus elastisitas (E) = 2400 kN/m2 . Kemudian dari hasil running plaxis diperoleh deformasi sebesar 0.1601 meter se-dangkan yang dihasilkan dengan metode Steinbrenner penurunan yang dihasilkan sebesar 0,1232 m. yang mengakibatkan plate footing pondasi tapak patah. Te-gangan yang terjadi pada tanah sebesar 0.012 kN/m2 dan dari hasil analisis di-peroleh faktor aman (safety factor) sebesar 1 (satu). The lower structure of a building construction consists of a foundation and a lay-er of soil to support the load of the upper construction. The condition of the soil under the structure is closely related to the behavior of the soil itself when it re-ceives loads, for example failures that occur in the sub-grade of the embankment foundation, namely the foundation soil is too soft so that the carrying capacity of the soil to withstand the load of the embankment is small, as a result the settle-ment that occurs is too large. So the soil layer under the structure must be strong, stable, safe, so that it does not decrease, does not break, because it will be diffi-cult to repair a foundation system. The purpose of this study was to determine the effect of embankment soil on a footing foundation and how much settlement was caused to the foundation. The Plaxis D2 V20 method is a finite element method that aims to analyze and design the geotechnical field. Soil samples were taken at the hospital. Wulan Windi, Medan City, using manual tools. The embankment soil investigation aims to determine the nature and characteristics of the embankment soil carried out at the Civil Engineering Laboratory of the Medan Area University and the Medan State Polytechnic laboratory. The results of the soil embankment | en_US |
dc.language.iso | id | en_US |
dc.publisher | Universitas Medan Area | en_US |
dc.relation.ispartofseries | NPM;168110089 | - |
dc.subject | pengaruh tanah | en_US |
dc.subject | tanah timbun | en_US |
dc.subject | elemen hingga plaxis | en_US |
dc.subject | 2d v20 | en_US |
dc.title | Pengaruh Tanah Timbunan Terhadap Daya Dukung Pondasi Telapak (Square Footing) | en_US |
dc.title.alternative | The Effect of Embankment Soil on the Bearing Capacity of the Footing (Square Footing) | en_US |
dc.type | Thesis | en_US |
Appears in Collections: | SP - Civil Engineering |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
168110089 - Beni Deni Sitompul - Fulltext.pdf | Cover, Abstract, Chapter I,II,III,Bibliography | 2.14 MB | Adobe PDF | View/Open |
168110089 - Beni Deni Sitompul - Chapter IV.pdf Restricted Access | Chapter IV | 1.4 MB | Adobe PDF | View/Open Request a copy |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.