dc.description.abstract | Pondasi adalah bagian terendah dari bangunan yang meneruskan beban bangunan ke tanah atau batuan yang berada dibawahnya (Hardiyatmo, 1996). Dari cara mendukung beban, perhitungan kapasitas dukung tiang dilakukan untuk mengetahui seberapa besar kemampuan tiang pancang untuk meneruskan beban yang bekerja terhadap lapisan tanah. Tujuan dari penulisan ini adalah untuk menghitung dan membandingkan kapasitas daya dukung tiang pancang tunggal menggunakan data sondir dan Standar Penetrasi Tes (SPT), dan menghitung kapasitas kelompok tiang yang paling efisien. Metodologi pengumpulan data dilakukan dengan cara melakukan observasi, pengambilan data dari pihak proyek serta melakukan studi keperpustakaan. Pada perhitungan daya dukung tiang pancang tunggal, berdasarkan data sondir menggunakan metode Aoki De Alancer dan Mayerhoff dan data SPT menggunakan metode Mayerhoff. Hasil perhitungan nilai kapasitas daya dukung ultimit tiang tunggal sebesar 647,656 ton dan 802,207 ton berdasarkan data sondir dengan menggunakan metode Aoki de Alancer dan Mayerhoff sedangkan untuk data SPT dengan menggunakan metode Mayerhoff sebesar 173,952 dan dari bacaan alat hydraulic didapat sebesar 288 ton. Dari hasil perhitungan didapat kapasitas kelompok ijin tiang yang paling efisien adalah 647,40 ton dengan menggunakan metode Aoki De Alancer. Abstract Foundation is the lowest part of the building that continues the building load to the ground or rock beneath it (Hardiyatmo, 1996). From the method of supporting the load, the calculation of the pole carrying capacity is carried out to determine the amount of the pile's ability to carry the load acting on the soil layer. The purpose of this paper is to calculate and compare the capacity of a single pile carrying capacity using sondir data and Standard Penetration Test (SPT), and calculate the most efficient pile group capacity. The data collected by conducting observations, retrieving data from the project and doing library studies. In calculating the carrying capacity of a single pile, based on sondir data using the Aoki De Alancer and Mayerhoff method and SPT data using the Mayerhoff method. The results of the calculation of the value of single pile ultimate carrying capacity of 647,656 tons and 802,207 tons based on sondir data using the Aoki de Alancer and Mayerhoff method and for SPT data using the Mayerhoff method of 173,952 tons from the readings of the hydraulic tools, it was obtained at 288 tons. From the calculation results, the most efficient capacity of the pile permit group is 647,40 tons using the Aoki de Alancer method. | en_US |
dc.language.iso | id | en_US |
dc.publisher | Universitas Medan Area | en_US |
dc.relation.ispartofseries | NPM;188110045 | - |
dc.subject | tiang pancang | en_US |
dc.subject | kapasitas daya dukung | en_US |
dc.subject | sondir | en_US |
dc.subject | piling | en_US |
dc.subject | carrying capacity | en_US |
dc.title | Analisis Daya Dukung Pondasi Tiang Pancang pada Pembangunan Rumah Sakit Regina Maris Medan | en_US |
dc.title.alternative | Analysis of the Carrying Capacity of Pile Foundations in the Construction of Regina Maris Hospital Medan | en_US |
dc.type | Skripsi Sarjana | en_US |
Appears in Collections: | SP - Civil Engineering |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
188110045 - Barita Edwar - Fulltext.pdf | Cover, Abstract, Chapter I, II, III, V, Bibliography | 1.38 MB | Adobe PDF | View/Open |
188110045 - Barita Edwar - Chapter IV.pdf Restricted Access | Chapter IV | 407.76 kB | Adobe PDF | View/Open Request a copy |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.