dc.description.abstractSaat merencanakan pembangunan sebuah gedung pertokoan, maupun apartemen, diperlukan lahan parkir yang terbilang cukup luas. Hal ini yang menjadi permasalahan tersendiri bagi pengembang (developer) karena tidak memungkinkan lagi membangun sebuah konstruksi secara horizontal karena keterbatasan lahan dan harga lahan yang semakin tinggi setiap waktunya. Oleh karena itu pembangunan basement merupakan bagian yang penting dari sebuah gedung bertingkat yang memanfaatkan luasan areal tanah yang ada sebagai area lahan parkir seperti pada pembangunan Proyek Rumah Sakit Regina Maris Medan. Pada pembangunan diawali dengan pekerjaan penggalian tanah yang merupakan awal dari pembangunan gedung bertingkat dengan berbagai ketinggian. Kendala yang timbul pada saat pengerjaan galian basement adalah faktor runtuhnya dinding tanah vertikal. Untuk menghindari keruntuhan pada saat penggalian basement, maka sebelum dilakukan penggalian tanah dibuat pengaman galian dengan memasang dinding penahan tanah. Pengamanan galian proyek Rumah Sakit Regina Maris Medan berupa retaning wall yang terdiri dari susunan batang spun pile yang diperkuat dengan strutting. Penelitian ini bertujuan untuk mengetahui aman atau tidaknya kondisi tanah pada saat penggalian untuk pembangunan basement. Metode dalam perhitungan stabililtas dinding penahan tanah menggunakan metode Rankine serta penggunaan alat bantu sofware Plaxis. Hasil dari perhitungan stabilitas terhadap guling menggunakan metode rankine memiliki nilai faktor keamanan 2.54 >1,50 untuk stabilitas terhadap guling dan juga stabilitas terhadap geser memliki nilai faktor aman (SF) 2,447>2.0. Sedangkan hasil analisis menggunakan sofware plaxis deformasi yang aman pada proses instalisasi retaining wall spun pile serta proses penggalian 1 dengan nilai faktor keamanannya adalah 1.81 dan pada penggalian ke 2 diperoleh nilai faktor keamanan (SF) 1.82 dan yang terakhir adalah penggalian 3 dengan nilai keamananya adalah 2.95. Berdasarkan data hasil perhitungan diatas maka disimpulkan bahwa dinding penahan tanah pada metode rankine dan software plaxis 8.6 nilai kapasitas yang didapat merupakan nilai yang tinggi serta aman terhadap keruntuhan. When planning the construction of a shopping building, or an apartment, a fairly large parking area is needed. This is a separate problem for developers because it is no longer possible to build a construction horizontally because of limited land and land prices that are getting higher every time. Therefore the construction of a basement is an important part of a multi-storey building that utilizes the existing land area as a parking area such as the construction of the Medan Regina Maris Hospital Project. The construction begins with excavation work which is the beginning of the construction of multi-storey buildings with various heights. Obstacles that arise during the basement excavation work are the collapse of the vertical soil walls. In order to avoid collapse during the excavation of the basement, prior to excavation the soil is made to protect the excavation by installing a retaining wall. Securing the excavation for the Regina Maris Medan Hospital project in the form of a retaning wall consisting of an arrangement of spun pile rods reinforced with strutting. This study aims to determine whether or not the condition of the soil is safe during excavation for basement construction. The method for calculating the stability of retaining walls uses the Rankine method and the use of Plaxis software tools. The results of the calculation of stability against overturning using the Rankine method have a factor of safety value of 2.54 > 1.50 for stability against overturning and also stability against shear having a factor of safety (SF) of 2.447 > 2.0. While the results of the analysis using safe deformation plaxis software in the retaining wall spun pile installation process and excavation process 1 with a safety factor value of 1.81 and in the 2nd excavation the safety factor value (SF) is 1.82 and the last is excavation 3 with a safety value of 2.95. Based on the data from the calculation above, it can be concluded that the retaining wall in the Rankine method and the Plaxis 8.6 software has a high capacity value and is safe from collapse.en_US
dc.language.isoiden_US
dc.publisherUniversitas Medan Areaen_US
dc.relation.ispartofseriesNPM;188110005-
dc.subjectdinding penahan tanahen_US
dc.subjectperkuatan dinding penahanen_US
dc.subjectspun pileen_US
dc.subjectplaxisen_US
dc.subjectfaktor keamananen_US
dc.subjectretaining wallen_US
dc.subjectstruttingen_US
dc.subjectsafety factoren_US
dc.titleAnalisis Stabilitas Struktur Retaining Wall Basement Rumah Sakit Regina Maris Terhadap Tekanan Tanah dengan Aplikasi Plaxis 8.6en_US
dc.title.alternativeStability Analysis of the Retaining Wall Basement Structure of Regina Maris Hospital Against Soil Pressure with the Application of Plaxis 8.6en_US
dc.typeThesisen_US
Appears in Collections:SP - Civil Engineering

Files in This Item:
File Description SizeFormat 
188110005 - Tommy Prasetyo Wibowo Fulltext.pdfCover, Abstract, Chapter I, II, III, V, Bibliography2.26 MBAdobe PDFView/Open
188110005 - Tommy Prasetyo Wibowo Chapter IV.pdf
  Restricted Access
Chapter IV1.18 MBAdobe PDFView/Open Request a copy


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.