Please use this identifier to cite or link to this item: https://repositori.uma.ac.id/handle/123456789/27562
Title: Analisa Respon Spektrum Struktur Gedung Bertingkat
Other Titles: Response Spectrum Analysis of Multi-storey Building Structures
Authors: Nasution, Abdul Farhan Hakim
metadata.dc.contributor.advisor: Irwan
Suranto
Keywords: Building Structure Analysis;Structural Performance;SAP2000.V20;Analisa Struktur Gedung;Kinerja Structural
Issue Date: 29-Jul-2023
Publisher: Universitas Medan Area
Series/Report no.: NPM;168110037
Abstract: Gempa merupakan fenomena alam yang tidak dapat di prediksi besar dan waktu terjadinya . Ditinjau dari segi intensitasnya, gempa bervariasi dari gempa kecil, sedang, bahkan gempa besar, untuk merancang bangunan tinggi, gempa bumi merupakan salah satu factor yang sangat diperhitungkan, mengingat gempa akan mengakibatkan guncangan dan goyangan yang dapat merusak struktur bangunan, Gempa adalah suatu bencana yang kerap sekali terjadi yang dapat menyebabkan beberapa masalah kerusakan pada bangunan, karna dapat menyebabkan penurunan kekuatan dan kekakuan dari bangunan tersebut,. Gedung Asrama BBPPMPV medan yang terletak di jalan Setia Budi Medan Helvetia, oleh karena itu perlu dilakukan analisis Kembali evaluasi ketahanan bangunan Gedung tersebut yang sesuai dengan standar yang berlaku. Dari pejelasan di atas, maka pada tugas akhir ini akan dilakukan analisis kinerja struktur dengan menggunakan analisis dinamik respon spektrum pada bangunan Gedung Asrama BBPPMPV Medan menggunakan software SAP2000. Penelitian ini dilakukan dengan mengumpulkan data premier dan skunder, data premier di dapat dari Gedung yang di tinjau sedangkan data skunder merupakan data yang diperlukan untuk melengkapi penelitian. Kegiatan analisis dibantu dengan menggunakan program SAP2000. Langkah analaisis dilakukan sesuai dengan prosedur yang telah di tetapkan. Bentuk data yang dikumpulkan dalam penelitian ini adalah gambar bestek bangunan, yang di pergunakan untuk pemodelan struktur 3d di dalam program SAP2000. Level kinerja bangunan Asrama BBPPMPV Medan menurut metode ATC-40 adalah immediate Occupancy, yaitu apabila terjadi gempa , hanya sedikit kerusakan structural terjadi , sehingga bangunan aman dan dapat langsung di pakai. Terjadinya sendi plastis pada balok kolom, pushover arah X terjadi pada balok lantai 2 dan 3, mulai dari step 2 dan seterusnya, hanya saja ada beberapa kondisi Dimana sendi plastis mencapai keterangan LS. Sama halnya dengan arah X, pushover arah Y hampIr sama yang terjadi Pada arah X yang mencapai keterangan LS Dimana jika terjadi kerusakan mulai dari kecil hingga Tingkat sedang, kekuatan struktur berkurang tetapi masih memiliki kekuatan yang cukup besar terhadap keruntuhan. Earthquakes are natural phenomena that cannot be predicted, the magnitude and time of occurrence. In terms of intensity, earthquakes vary from small, medium, even large earthquakes, for designing tall buildings, earthquakes are one of the factors that are taken into account, considering that earthquakes will cause shocks and shaking that can damage building structures. Earthquakes are a disaster that This often happens which can cause several damage problems to the building, because it can cause a decrease in the strength and stiffness of the building. The BBPMPPV Medan Dormitory Building is located on Jalan Setia Budi Medan Helvetia, therefore it is necessary to re-evaluate the building's durability in accordance with applicable standards. From the explanation above, in this final project a structural performance analysis will be carried out using dynamic response spectrum analysis in the BBPMPPV Medan Dormitory Building using SAP2000 software. This research was carried out by collecting primary and secondary data, primary data was obtained from the building being reviewed while secondary data was the data needed to complete the research. Analysis activities are assisted using the SAP2000 program. The analysis steps were carried out in accordance with established procedures. The form of data collected in this research is bestek building drawings, which are used for 3D structural modeling in the SAP2000 program. The performance level of the BBPPMPV Medan Dormitory building according to the ATC-40 method is immediate occupancy, that is, if an earthquake occurs, only minimal structural damage occurs, so the building is safe and can be used immediately. Plastic joints occur in column beams, pushover in the X direction occurs in floor beams 2 and 3, starting from step 2 onwards, but there are several conditions where the plastic joints reach the LS description. Similar to the X direction, almost the same pushover in the Y direction occurs in the
Description: 71 Halaman
URI: https://repositori.uma.ac.id/handle/123456789/27562
Appears in Collections:SP - Civil Engineering

Files in This Item:
File Description SizeFormat 
168110037 - Abdul Farhan Hakim Nasution - Chapter IV.pdf
  Restricted Access
Chapter IV1.68 MBAdobe PDFView/Open Request a copy
168110037 - Abdul Farhan Hakim Nasution - Fulltext.pdfCover, Abstract, Chapter I, II, III, V, Bibliography1.49 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.