dc.description | Bencana meletusnya Gunung Merapi Sinabung pada tahun 2014 menyisakan banyak material abu vulkanik yang belum termanfaatkan dengan baik. Abu vulkanik termasuk kedalam bahan pozolan alami karena mengandung unsur silika dan alumina sehingga dapat mengurangi pemakaian jumlah semen Portland dalam suatu adukan beton. Abu vulkanik Sinabung ini dicoba digunakan untuk mengurangi jumlah pemakaian semen dalam campuran beton dengan mutu beton K-175. Penelitian ini direncanakan dengan membuat Mix Design. Penelitian ini bertujuan untuk mengetahui pengaruh penggunaan abu vulkanik sebagai substitusi semen terhadap besar kuat tekan beton K-175. Benda uji yang digunakan adalah silinder beton dengan ukuran diameter 150 mm dan tinggi 300 mm. Jumlah benda uji untuk setiap variasi 20 buah benda uji. Hasil pengujian kuat tekan beton rata-rata untuk Beton Normal 210,9 kg/cm2, Variasi Abu Vulkanik 20% adalah 177,1 kg/cm2, Variasi abu vulkanik 50% adalah 113,2 kg/cm2 untuk umur 28 hari. | en_US |
dc.description.abstract | Mount Merapi eruption in 2014 leaves a lot of material volcanic ash are not utilized well. Volcanic ash into materials including natural Pozolan because it contains elements of silica and alumina so as to reduce the usage amount of Portland cement in the concrete mix. Sinabung volcanic ash used to try to reduce the amount of consumption of cement in the concrete mix quality K-175. The study was planned to make the Mix Design. This study to determine the effect of the use of ash as a cement substitute for the concrete compressive strength testing K-175. Specimens used are concrete cylinders with a diameter of 150 mm and a height of 300 mm. Number of test specimens for each variation of 20 specimens. Concrete compressive strength test results mean for Normal Concrete 210.9 kg / cm2, Variation 20% Volcanic Ash was 177.1 kg / cm2, 50% Variation of volcanic ash was 113.2 kg / cm2 for 28 days. | en_US |
dc.language.iso | id | en_US |
dc.publisher | Universitas Medan Area | en_US |
dc.subject | abu vulkanik sinabung | en_US |
dc.subject | pozzolan | en_US |
dc.subject | kuat tekan | en_US |
dc.subject | mix design | en_US |
dc.subject | sinabung volcanic ash | en_US |
dc.subject | compressive strength | en_US |
dc.title | Pengaruh Abu Vulkanik Gunung Sinabung sebagai Substitusi Semen Terhadap Kuat Tekan Beton | en_US |