Please use this identifier to cite or link to this item: https://repositori.uma.ac.id/handle/123456789/22131
Title: Analisis Daya Dukung Pondasi Tiang Pancang Pada Proyek Pembangunan Apartemen Princeton Boutique Living Medan
Other Titles: Analysis of the Bearing Capacity of Pile Foundations in the Princeton Boutique Living Medan Apartment Construction Project
Authors: Simanjuntak, Wilman
metadata.dc.contributor.advisor: Lubis, Kamaluddin
Keywords: Pile Foundation;Support Capacity;Sondir;Pondasi Tiang Pancang;Kapasitas Daya Dukung
Issue Date: 3-Jul-2023
Publisher: Universitas Medan Area
Series/Report no.: NPM;198110108
Abstract: Pondasi tiang atau disebut juga pondasi dalam dipergunakan untuk konstruksi beban berat. Sebelum melaksanakan suatu pembangunan konstruksi pertama dilaksanakan dan dikerjakan adalah pekerjaan pondasi (struktur bawah). Pondasi merupakan suatu pekerjaan yang sangat penting dalam suatu pekerjaan teknik sipil, karena pondasi inilah yang memikul dan menahan suatu beban yang bekerja diatasnya yaitu beban konstruksi atas. Metode yang digunakan dalam penelitian ini adalah metode Mayerhoff dan Metode Aoki De Alencar untuk tiang pancang tunggal dan untuk tiang kelompok atau group digunakan Metode Converse Labare dan Metode Los Angeles Group. Tujuan dari penelitian ini adalah untuk Memperoleh kapasitas daya dukung pondasi tiang pancang tunggal dan kapasitas efesiensi tiang pancang kelompok. Dari hasil perhitungan daya dukung tiang pancang tunggal,pada kedalaman 6,20 meter berdasarkan data sondir (CPT-2) dengan metode Aoki de Aleancer Qult= 506,082 ton dan metode Mayerhoff Qult= 1096,7392 ton, dari data SPT-BH1 menggunakan metode Mayerhoff Qult=177,81 ton. Hasil dari perhitungan efesiensi kelompok tiang didapat kapasitas kelompok ijin tiang yang paling efesien adalah 9671,603ton dengan menggunakan metode Converse Labarre. Peneliti menyimpulkan sebab itu pondasi akan aman jika daya dukung pondasi lebih besar dari pada beban-beban yang bekerja pada bangunan Apartemen Princeton Boutique Living. Pile foundations or also called deep foundations are used for heavy load construction. Before carrying out a construction the first construction carried out and done is foundation work (lower structure). The foundation is a very important work in a civil engineering job, because it is this foundation that bears and holds a load that works above it, namely the upper construction load. The methods used in this research are the Mayerhoff method and the Aoki De Alencar Method for single piles and for group or group piles the Converse Labare Method and the Los Angeles Group Method are used. The purpose of this research is to obtain the bearing capacity of single pile foundation and the efficiency capacity of group piles. From the calculation of the bearing capacity of a single pile, at a depth of 6.20 meters based on sondir data (CPT-2) with the Aoki de Aleancer method Qult = 506.082 tons and the Mayerhoff method Qult = 1096.7392 tons, from SPT-BH1 data using the Mayerhoff method Qult = 177.81 tons. The results of the calculation of the efficiency of the pile group obtained the capacity of the most efficient pile permit group is 9671.603 tons using the Converse Labarre method. The researcher concluded that therefore the foundation will be safe if the bearing capacity of the foundation is greater than the loads acting on the Princeton Boutique Living Apartment building.
Description: 83 Halaman
URI: https://repositori.uma.ac.id/handle/123456789/22131
Appears in Collections:SP - Civil Engineering

Files in This Item:
File Description SizeFormat 
198110108 - Wilman Simanjuntak - Fulltext.pdfCover, Abstract, Chapter I, II, III, V, Bibliography2.99 MBAdobe PDFView/Open
198110108 - Wilman Simanjuntak - Chapter IV.pdf
  Restricted Access
Chapter IV633.03 kBAdobe PDFView/Open Request a copy


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.